Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cir Esp (Engl Ed) ; 101(7): 482-489, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36265771

RESUMO

INTRODUCTION: The acquisition of laparoscopic technique skills in an operating room is conditioned by the expertise of the tutor and the number of training interventions by the trainee. For students and surgeons to use a laparoscopic simulator to train their skills, it must be validated beforehand. METHODS: A laparoscopic simulator box was designed, along with 6 interchangeable training games. The simulator was validated by a group of 19 experts, physicians with an experience from at least 100 laparoscopic surgeries, and 20 students of 4th to 6th grades of medical school (non-experts). To evaluate its construct validity, time-to-completion and the number of successfully completed games were assessed. We used 11 and 9-item questionnaires to gather information on content and face validity respectively. In both questionnaires, answers were collected through Likert-type scales, scored from 1 to 5. RESULTS: The group of experts required less time and successfully completed more games than the group of non-experts (p < 0.01). The group of non-experts gave a score ≥ 4 points on each of the questions regarding the content validity of the tool, however, the experts rated with a significant lower mean score the need for the simulator to learn the surgical technique (3.68 points; p < 0.01). Regarding the face validity, all items were graded with a score ≥ 4 points except for the question relating to the spatial realism (3.82 points). CONCLUSION: The laparoscopy simulation box and the games were valid means for training surgeons and medical students to develop the skills required for the laparoscopic technique.


Assuntos
Laparoscopia , Cirurgiões , Humanos , Laparoscopia/métodos , Simulação por Computador
2.
J Voice ; 2022 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-36210222

RESUMO

PURPOSE: There are many physiological parameters recorded by devices that are becoming more affordable, precise and accurate. However, the lack of development in the recording of voice parameters from the physiological or medical point of view is striking, given that it is a fundamental tool for the work of many people and given the high incidence and prevalence of voice pathologies that affect people's communication. In this paper we perform a complete literature review on the dosimeters used in voice research and to present a prototype dosimeter with a pilot study to show its capabilities. METHOD: We conducted a literature review using the keywords [MONITORING], [PHONATION], [ACCUMULATOR], [PORTABLE], [DOSIMETRY], [VOICE] searching in PubMed, Trip Database, HONcode, and SciELO search engines. From our review of dosimeter designs, we created our own prototype consisting of two main components: a Knowles Electronics BU-7135-0000 accelerometer mounted on a neck brace; and the ultra-low power MSP430FR5994 microcontroller. The selected sampling frequency was 2048 Hz. The device calculates the F0 every 250 ms and the amplitude and phonation activity every 31.25 ms. A pilot study was conducted using 2 subjects: one male during 11 days and one female during 14 days. RESULTS: This work includes devices that have been created during the last 45 years as tools for the diagnosis and monitoring of the treatment of cases of vocal pathology and for the detection of phonatory patterns or risk situations for developing voice disorders or vocal pathologies. We also present recordings with our new device on the pattern of daily talk time, the fundamental frequency and the relative intensity of two subjects on different days. CONCLUSIONS: Interesting work has been done in the development of voice dosimeters with different approaches. In our experience it is not possible to access them for research and they are not yet in clinical use. It is possible that a joint approach with voice and voice disorders professionals and engineers working closely together could take advantage of current technology to develop a fully portable, useful, and efficient system.

3.
Cir Esp (Engl Ed) ; 2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-35985573

RESUMO

INTRODUCTION: The acquisition of laparoscopic technique skills in an operating room is conditioned by the expertise of the tutor and the number of training interventions by the trainee. For students and surgeons to use a laparoscopic simulator to train their skills, it must be validated beforehand. METHODS: A laparoscopic simulator box was designed, along with 6 interchangeable training games. The simulator was validated by a group of 19 experts, physicians with an experience from at least 100 laparoscopic surgeries, and 20 students of 4th to 6th grades of medical school (non-experts). To evaluate its construct validity, time-to-completion and the number of successfully completed games were assessed. We used 11 and 9-item questionnaires to gather information on content and face validity respectively. In both questionnaires, answers were collected through Likert-type scales, scored from 1 to 5. RESULTS: The group of experts required less time and successfully completed more games than the group of non-experts (p < 0.01). The group of non-experts gave a score ≥4 points on each of the questions regarding the content validity of the tool, however, the experts rated with a significant lower mean score the need for the simulator to learn the surgical technique (3.68 points; p < 0.01). Regarding the face validity, all items were graded with a score ≥4 points except for the question relating to the spatial realism (3.82 points). CONCLUSION: The laparoscopy simulation box and the games were valid means for training surgeons and medical students to develop the skills required for the laparoscopic technique.

4.
Biomed Eng Online ; 15(1): 52, 2016 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-27160751

RESUMO

BACKGROUND: Laryngo-pharyngeal mechano-sensitivity (LPMS) is involved in dysphagia, sleep apnea, stroke, irritable larynx syndrome and cough hypersensitivity syndrome among other disorders. These conditions are associated with a wide range of airway reflex abnormalities. However, the current device for exploring LPMS is limited because it assesses only the laryngeal adductor reflex during fiber-optic endoscopic evaluations of swallowing and requires a high degree of expertise to obtain reliable results, introducing intrinsic expert variability and subjectivity. METHODS: We designed, developed and validated a new air-pulse laryngo-pharyngeal endoscopic esthesiometer with a built-in laser range-finder (LPEER) based on the evaluation and control of air-pulse variability determinants and on intrinsic observer variability and subjectivity determinants of the distance, angle and site of stimulus impact. The LPEER was designed to be capable of delivering precise and accurate stimuli with a wide range of intensities that can explore most laryngo-pharyngeal reflexes. RESULTS: We initially explored the potential factors affecting the reliability of LPMS tests and included these factors in a multiple linear regression model. The following factors significantly affected the precision and accuracy of the test (P < 0.001): the tube conducting the air-pulses, the supply pressure of the system, the duration of the air-pulses, and the distance and angle between the end of the tube conducting the air-pulses and the site of impact. To control all of these factors, an LPEER consisting of an air-pulse generator and an endoscopic laser range-finder was designed and manufactured. We assessed the precision and accuracy of the LPEER's stimulus and range-finder according to the coefficient of variation (CV) and by looking at the differences between the measured properties and the desired values, and we performed a pilot validation on ten human subjects. The air-pulses and range-finder exhibited good precision and accuracy (CV < 0.06), with differences between the desired and measured properties at <3 % and a range-finder measurement error of <1 mm. The tests in patients demonstrated obtainable and reproducible thresholds for the laryngeal adductor, cough and gag reflexes. CONCLUSIONS: The new LPEER was capable of delivering precise and accurate stimuli for exploring laryngo-pharyngeal reflexes.


Assuntos
Ar , Endoscopia/instrumentação , Laringe , Faringe , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Laringe/fisiologia , Masculino , Pessoa de Meia-Idade , Faringe/fisiologia , Pressão , Reflexo , Sensação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA